Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Radiol. bras ; 47(6): 333-341, Nov-Dec/2014. tab, graf
Article in English, Portuguese | LILACS-Express | LILACS | ID: lil-732744

ABSTRACT

Objetivo: Avaliar um protocolo de espectroscopia por ressonância magnética (ERM) do próton de hidrogênio (1H) bidimensional (2D) disponível comercialmente (Siemens Medical Systems; Erlangen, Alemanha), aplicado para nódulos adrenais e diferenciação das massas (adenomas, feocromocitomas, carcinomas e metástases). Materiais e Métodos: Um total de 118 pacientes (36 homens e 82 mulheres), apresentando-se com 138 nódulos/massas adrenais, foi avaliado prospectivamente (média de idade: 57,3 ± 13,3 anos). Uma sequência de ERM-1H-PRESS-CSI (espectroscopia por resolução de ponto-imagem por desvio químico) multivoxel foi utilizada. Análise espectroscópica foi realizada da esquerda-direita, sentido crânio-caudal, usando três sequências sagitais, além de sequências axiais e coronais T2-HASTE. Os seguintes índices foram calculados: colina (Cho)/creatina (Cr), 4,0–4,3 ppm/Cr, lipídio (Lip)/Cr, Cho/Lip e lactato (Lac)/Cr. Resultados: ERM-1H-2D foi bem sucedida em 123 (89,13%) lesões. Os valores de sensibilidade e especificidade encontrados para as proporções e pontos de corte avaliados foram: Cho/Cr ≥ 1,2, sensibilidade de 100% e especificidade de 98,2% (diferenciação de adenomas e carcinomas de feocromocitomas e metástases); 4,0–4,3 ppm/Cr ≥ 1,5, 92,3% de sensibilidade, especificidade de 96,9% (diferenciação de carcinomas e feocromocitomas de adenomas e metástases); Lac/Cr ≤ –7,449, sensibilidade de 90,9% e especificidade de 77,8% (diferenciação de feocromocitomas contra carcinomas e adenomas). Conclusão: Os dados da ERM-1H-2D foram eficazes e permitiram a diferenciação entre massas adrenais e nódulos na maioria das lesões com diâmetro > 1,0 cm. .


Objective: To evaluate a protocol for two-dimensional (2D) hydrogen proton (1H) magnetic resonance spectroscopy (MRS) (Siemens Medical Systems; Erlangen, Germany) in the detection of adrenal nodules and differentiation between benign and malignant masses (adenomas, pheochromocytomas, carcinomas and metastases). Materials and Methods: A total of 118 patients (36 men; 82 women) (mean age: 57.3 ± 13.3 years) presenting with 138 adrenal nodules/masses were prospectively assessed. A multivoxel system was utilized with a 2D point-resolved spectroscopy/chemical shift imaging sequence. The following ratios were calculated: choline (Cho)/creatine (Cr), 4.0–4.3/Cr, lipid (Lip)/Cr, Cho/Lip and lactate (Lac)/Cr. Results: 2D-1H-MRS was successful in 123 (89.13%) lesions. Sensitivity and specificity values observed for the ratios and cutoff points were the following: Cho/Cr ≥ 1.2, 100% sensitivity, 98.2% specificity (differences between adenomas/pheochromocytomas and carcinomas/ metastases); 4.0–4.3 ppm/Cr ≥ 1.5, 92.3% sensitivity, 96.9% specificity (differences between carcinomas/pheochromocytomas and adenomas/metastases); Lac/Cr ≤ –7.449, 90.9% sensitivity and 77.8% specificity (differences between pheochromocytomas and carcinomas/adenomas). Conclusion: Information provided by 2D-1H-MRS were effective and allowed for the differentiation between adrenal masses and nodules in most cases of lesions with > 1.0 cm in diameter. .

2.
Int. braz. j. urol ; 32(3): 336-341, May-June 2006. ilus
Article in English | LILACS | ID: lil-433383

ABSTRACT

OBJECTIVES: In this preliminary study we report the development of the video urodynamic technique using magnetic resonance imaging (MRI). MATERIALS AND METHODS: We studied 6 women with genuine stress urinary incontinence, diagnosed by history and physical examination. Urodynamic examination was performed on multichannel equipment with the patient in the supine position. Coughing and Valsalva maneuvers were performed at volumes of 150, 250 and 350 mL. Simultaneously, MRI was carried out by using 1.5 T GE Signa CV/i high-speed scanner with real time fluoroscopic imaging possibilities. Fluoroscopic imaging was accomplished in the corresponding planes with T2-weighted single shot fast spin echo sequences at a speed of about 1 frame per second. Both studies were recorded and synchronized, resulting in a single video urodynamic examination. RESULTS: Dynamic MRI with cine-loop reconstruction of 1 image per second demonstrated the movement of all compartment of the relaxed pelvis during straining with the concomitant registration of abdominal and intravesical pressures. In 5 patients, urinary leakage was demonstrated during straining and the Valsalva leak point pressure (VLPP) was determined as the vesical pressure at leak subtracted from baseline bladder pressure. Mean VLPP was 72.6 cm H2O (ranging from 43 to 122 cm H2O). CONCLUSIONS: The concept of MRI video urodynamics is feasible. In a clinical perspective, practical aspects represent a barrier to daily use and it should be recommended for research purposes.


Subject(s)
Adult , Aged , Female , Humans , Middle Aged , Magnetic Resonance Imaging/methods , Urinary Incontinence, Stress/physiopathology , Urinary Tract/physiopathology , Urodynamics/physiology , Valsalva Maneuver , Video Recording
3.
Arq. bras. endocrinol. metab ; 48(5): 592-611, out. 2004. ilus
Article in English | LILACS | ID: lil-393714

ABSTRACT

Procedimentos de imagem têm um papel vital na avaliação da patologia adrenal. As modalidades mais amplamente empregadas são a tomografia computadorizada e a imagem por ressonância magnética. Isoladas ou em combinação com dados clínicos e bioquímicos apropriados, a imagem pode prover diagnósticos específicos que dispensam a necessidade de amostras de tecido por biopsia. Este artigo revisa os achados de imagem da adrenal normal e patológica, incluindo tanto causas benignas como malignas.


Subject(s)
Humans , Adrenal Gland Neoplasms , Adrenal Gland Diseases/diagnosis , Adrenal Gland Neoplasms/diagnosis , Cushing Syndrome/diagnosis , Hyperaldosteronism/diagnosis , Magnetic Resonance Imaging , Neoplasm Metastasis , Pheochromocytoma/diagnosis , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL